2008年11月30日星期日

Varistor


Metal oxide varistor
The most common type of varistor is the Metal Oxide Varistor (MOV). This contains a ceramic mass of zinc oxide grains, in a matrix of other metal oxides (such as small amounts of bismuth, cobalt, manganese) sandwiched between two metal plates (the electrodes). The boundary between each grain and its neighbour forms a diode junction, which allows current to flow in only one direction. The mass of randomly oriented grains is electrically equivalent to a network of back-to-back diode pairs, each pair in parallel with many other pairs. When a small or moderate voltage is applied across the electrodes, only a tiny current flows, caused by reverse leakage through the diode junctions. When a large voltage is applied, the diode junctions break down due to a combination of thermionic emission and electron tunneling, and a large current flows. The result of this behaviour is a highly nonlinear current-voltage characteristic, in which the MOV has a high resistance at low voltages and a low resistance at high voltages.
For example, follow-through current as a result of a lightning strike may generate excessive current that permanently damages a varistor. In general, the primary case of varistor breakdown is localized heating caused as an effect of thermal runaway. This is due to a lack of conformality in individual grain-boundary junctions, which leads to the failure of dominant current paths under thermal stress.
Varistors can absorb part of a surge. How much effect this has on risk to connected equipment depends on the equipment and details of the selected varistor. Varistors do not absorb a significant percentage of a lightning strike as energy that must be conducted elsewhere is many orders of magnitude greater than what is absorbed by the small device.
A varistor remains non-conductive as a shunt mode device during normal operation when voltage remains well below its "clamping voltage". If a transient pulse (often measured in joules) is too high, the device may melt, burn, vaporize, or otherwise be damaged or destroyed. This (catastrophic) failure occurs when "Absolute Maximum Ratings" in manufacturer's datasheet are significantly exceeded. Varistor degradation is defined by manufacturer's life expectancy charts using curves that relate current, time, and number of transient pulses. A varistor fully degrades typically when its "clamping voltage" has changed by 10%. A fully degraded varistor remains functional (no catastrophic failure) and is not visually damaged.
Ballpark number for varistor life expectancy is its energy rating. As MOV joules increase, the number of transient pulses increases and the "clamping voltage" during each transient decreases. The purpose of this shunt mode device is to divert a transient so that pulse energy will be dissipated elsewhere. Some energy is also absorbed by the varistor because a varistor is not a perfect conductor. Less energy is absorbed by a varistor, the varistor is more conductive, and its life expectancy increases exponentially as varistor energy rating is increased. Catastrophic failure can be avoided by significantly increasing varistor energy ratings either by using a varistor of higher joules or by connecting more of these shunt mode devices in parallel.
Important parameters are a varistor's energy rating (in joules), response time (how long it takes the varistor to break down), maximum current and a well-defined breakdown (clamping) voltage. Energy rating is often defined using 'industry standard' transients such as 8/20 microseconds or 10/1000 microseconds. MOVs are intended for shunting short duration pulses. For example, 8 microseconds is a transient's rise time; 20 microseconds is the fall time.
To protect communications lines (such as telephone lines) transient suppression devices such as 3 mil carbon blocks (IEEE C62.32), ultra-low capacitance varistors or avalanche diodes are used. For higher frequencies such as radio communication equipment, a gas discharge tube (GDT) may be utilized.
A typical surge protector power strip is built using MOVs. A cheapest kind may use just one varistor, from hot (live, active) to neutral. A better protector would contain at least three varistors; one across each of the three pairs of conductors (hot-neutral, hot-ground, neutral-ground). A power strip protector in the United States should have a UL1449 2nd edition approval so that catastrophic MOV failure would not create a fire hazard.


Hazards
While a MOV is designed to conduct significant power for very short durations (~8/20 microseconds), such as caused by lightning strikes, it typically does not have the capacity to conduct sustained energy. Under normal utility voltage conditions, this is not a problem. However, certain types of faults on the utility power grid can result in sustained over-voltage conditions. Examples include a loss of a neutral conductor or shorted lines on the high voltage system. Application of sustained over-voltage to a MOV can cause high dissipation, potentially resulting in the MOV device catching fire. The National Fire Protection Association (NFPA) has documented many cases of catastrophic fires that have been caused by MOV devices in surge suppressors, and has issued bulletins on the issue.
A series connected thermal fuse is one solution to catastrophic MOV failure. A varistor with internal thermal protection is also available.
There are several issues to be noted regarding behavior of transient voltage surge suppressors (TVSS) incorporating MOVs under over-voltage conditions. Depending on the level of conducted current, dissipated heat may be insufficient to cause failure, but may degrade the MOV device and reduce its life expectancy. If excessive current is conducted by a MOV, it may explode inside the case, keeping the load connected but now without any surge protection. A user may have no indication when the surge suppressor has failed. Under the right conditions of over-voltage and line impedance, it may be possible to cause the MOV to burst into flames, the root cause of many fires and the main reason for NFPA’s concern. Properly designed TVSS devices should contain the flames, eventually resulting in the opening of a safety fuse.

What varistors don't do
Some consumers assume that a MOV inside a TVSS device provides equipment with complete power protection. Unfortunately, a MOV device and other types of surge suppressors provide no protection for the connected equipment from sustained over-voltages that may result in damage to that equipment as well as to the protector device. A potential fire hazard also exists.
A varistor provides no equipment protection from inrush current surges (during equipment startup), from overcurrent (created by a short circuit), or from voltage sags (also known as a brownout). A varistor neither senses nor controls such events. Susceptibility of electronic equipment to these other power disturbances is defined by equipment design. Protection from these power disturbances is installed inside that equipment or is provided by other external devices.

fsa bicycle parts


PTZ Dome Camera


14 ibook battery


bronze marine hardware


countdown clock timer


Water Pump Plier


Air Ratchet Wrench


Metal Oxide Varistor


volvo scan tool


aluminum oxide abrasive


tongkat ali extract


Glue Chip Glass


textile machinery spares


SNAP Lock Punch


Cardboard Counter Display


Dpdt Rocker Switch


C Band LNB


wrench ratchet set


Pin Tumbler Lock


CCD Module Camera


indoor dome camera


copper master alloy


Ku Satellite Dish


zoom stereo microscope


abb circuit breaker


Reverse Parking Sensor


digital thermometer waterproof


medical ozone generator


foil stamp machine


Car Wheel Balancer

没有评论: